Open Compute and data centre architectures

A new White Paper from Schneider Electric considers the capital costs of OCP-compliant data centres, including the implications for redundancy, availability and flexibility of upstream power infrastructure.

Schneider Electric has published White Paper #228: “Analysis of Data Center Architectures Supporting Open Compute Project.”

Kevin Brown, Senior Vice President of Data Center Solutions at Schneider Electric, said: “The Open Compute Project (OCP) has had a significant impact on data centre design, with the focus to date being primarily at the rack level. However, there are important implications for the provision of upstream power that need to be taken into account to ensure that expected levels of redundancy and maintainability can be delivered as well as the flexibility to support both traditional and OCP equipment.”

The new White Paper addresses three critical questions about electrical architecture to aid data centre managers in the decision making process when considering an OCP adoption:

1.       How do OCP rack/server designs affect the upstream electrical architecture?

2.       Can I still achieve 2N redundancy (sometimes referred to as tier 3)?

3.       How do I support traditional and OCP loads in the same data centre?

White Paper 228 describes cost comparisons between a number of scenarios including a traditional 2N data-centre architecture, an OCP-specific 1N architecture, an OCP-specific 2N architecture and a simplified 2N architecture with the flexibility to support mixed (i.e. traditional and OCP-specific) loads.

In broad terms, compared to a traditional 2N data centre, an OCP-specific 1N data centre offered capital-expenditure savings of 45%, when including MV switchgear down to and including rack and server power supplies. The White Paper shows that the reduction in redundancy and server power-supply differences represents the majority of the savings.

An OCP-specific 2N data centre offered savings of 25%.  Of that savings, 14% is attributed to architecture simplification and thus is independent of load type. 

A simplified 2N architecture that is flexible to support mixed loads has a small premium of 3% over an OCP-specific architecture.  Mixed load environments are most likely to be adopted in the coming years as data centers migrate their end-of-life traditional equipment.  The white paper provides a sensitivity analysis to show how the server power supply cost and the load mix (%) impacts the overall architecture costs.

First of its kind research, in partnership with Canalys, offers deep insights into some of the...
According to a recently published report from Dell’Oro Group, worldwide data center capex is...
Managed service providers (MSPs) are increasing their spending by as much as 70% to meet growing...
Coromatic, part of the E.ON group and the leading provider of robust critical infrastructure...
Datto’s Global State of the MSP: Trends and Forecasts for 2024 underscores the importance of...
Park Place Technologies has appointed Ian Anderson as Senior Director, Channel Sales, EMEA.
Node4 has passed the ISO 27017 and ISO 27018 audits, reinforcing its dedication to data security,...
Park Place Technologies has acquired Xuper Limited, an IT solutions provider based in Derby, UK.